B:
Transfer 100 mg to a 15-mL centrifuge tube containing 2.0 mL of diluted alcohol and 1.0 mL of
lead acetate TS, mix, shake, and boil for 2 minutes. Centrifuge, decant the supernatant into a second 15-mL centrifuge tube, add 2.0 mL of chloroform, and mix. Centrifuge, then remove the lower layer, and filter it through a chloroform-washed small column of anhydrous sodium sulfate (100 to 300 mg) into a 5-mL centrifuge tube. Evaporate the chloroform solution under a stream of nitrogen to dryness, and dissolve the residue in 100 µL of a mixture of methanol and chloroform (1:1). Prepare a Standard solution in the same manner, using 100 mg of
USP Digitalis RS (
Standard solution A). Prepare a second Standard solution by dissolving
USP Digitoxin RS and
USP Gitoxin RS in a mixture of methanol and chloroform (1:1) such that the final concentration of each is approximately 0.2 mg per mL (
Standard solution B). Apply 10 µL of the test solution, 10 µL of
Standard solution A, and 10 µL of
Standard solution B, each as a narrow band about 15 mm long, to a suitable thin-layer chromatographic plate (see
Chromatography 621) coated with a 0.25-mm layer of chromatographic silica gel mixture, and allow the bands to dry. Develop the chromatogram in a saturated chamber, using a solvent system consisting of a mixture of ethyl acetate, methanol, and water (30:4:3) until the solvent front has moved about 15 cm from the origin. Mix 10 mL of chloramine T solution (3 in 100) with 40 mL of a 1 in 4 solution of trichloroacetic acid in alcohol (store the mixture in a cool place, and use it within 1 week), and spray the air-dried chromatographic plate with this mixture. Heat the plate at 110
for 15 to 20 minutes, and examine it under long-wavelength UV light. Locate the 2 prominent bands obtained from
Standard solution A corresponding in
RF value to the 2 bands obtained from
Standard solution B. The chromatogram obtained from the solution under test shows bands corresponding to them, and also shows bands corresponding to the 3 other bands most prominent in the chromatogram from
Standard solution A but of lower
RF value. Relative
RF values for the 5 bands are: 1.0 (digitoxin); 0.8 to 0.9 (gitoxin); 0.6 to 0.7; 0.4 to 0.5; and 0.3 to 0.4.