Packaging and storage
Preserve in well-closed containers. Store at 25
, excursions permitted between 15
and 30
.
Chromatographic purity
Standard solutions
Dissolve
USP Tolazoline Hydrochloride RS in methanol, and mix to obtain
Standard solution A having a known concentration of 100 µg per mL. Quantitatively dilute with methanol to obtain
Standard solutions, designated below by letter, having the following compositions:
Standard
solution |
Dilution |
Concentration (µg RS per mL) |
Percentage (%, for comparison with test specimen) |
A |
undiluted |
100 |
0.5 |
B |
4 in 5 |
80 |
0.4 |
C |
3 in 5 |
60 |
0.3 |
D |
2 in 5 |
40 |
0.2 |
E |
1 in 5 |
20 |
0.1 |
Test solution
Dissolve an accurately weighed quantity of Tolazoline Hydrochloride in methanol to obtain a solution containing 20 mg per mL.
Identification solution
Quantitatively dilute a portion of the Test solution with methanol to obtain a solution containing 100 µg per mL.
Detection reagent
Prepare (1) a solution of 0.5 g of potassium iodide in 50 mL of water, and (2) a solution of 1.5 g of soluble starch in 50 mL of boiling water. Just prior to use, mix 10 mL of each solution with 3 mL of alcohol.
Procedure
Apply separately 5 µL of the
Test solution, 5 µL of the
Identification solution, and 5 µL of each
Standard solution to a suitable thin-layer chromatographic plate (see
Chromatography 621) coated with a 0.25-mm layer of chromatographic silica gel. Position the plate in a chromatographic chamber, and develop the chromatograms in a solvent system consisting of a mixture of methanol and ammonium hydroxide (95:5) until the solvent front has moved about three-fourths of the length of the plate. Remove the plate from the developing chamber, mark the solvent front, and allow the plate to dry under a current of warm air for at least 30 minutes. Expose the plate to chlorine gas for not more than 5 minutes, and air-dry until the chlorine has dissipated (about 15 minutes). Spray the plate with
Detection reagent, and immediately compare the intensities of any secondary spots observed in the chromatogram of the
Test solution with those of the principal spots in the chromatograms of the
Standard solutions: the sum of the intensities of all secondary spots obtained from the
Test solution corresponds to not more than 1.0%.
Assay
Dissolve about 300 mg of Tolazoline Hydrochloride, accurately weighed, in 100 mL of glacial acetic acid; add 25 mL of
mercuric acetate TS; and titrate with 0.1 N perchloric acid VS, determining the endpoint potentiometrically (see
Titrimetry 541), using a calomelglass electrode system. Perform a blank determination, and make any necessary correction. Each mL of 0.1 N perchloric acid is equivalent to 19.67 mg of C
10H
12N
2·HCl.