Chromatographic purity
Solution A
Prepare a filtered and degassed mixture of 5.0 mL of morpholine with 995 mL of water, and adjust with phosphoric acid to a pH of 7.0.
Solution B
Prepare a filtered and degassed mixture of methanol, acetonitrile, and tetrahydrofuran (1:1:1). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Mobile phase
Use variable mixtures of
Solution A and
Solution B as directed for
Chromatographic system (see
System Suitability under
Chromatography 621).
Standard solution 1
Dissolve an accurately weighed quantity of
USP Pergolide Mesylate RS in methanol, and dilute quantitatively, and stepwise if necessary, with methanol to obtain a solution having a known concentration of about 30 µg per mL.
Standard solution 2
Dilute 10.0 mL of Standard solution 1 to 50 mL with methanol.
Test solution
Transfer about 60 mg of Pergolide Mesylate, accurately weighed, to a 10-mL volumetric flask, dissolve in and dilute with methanol to volume, and mix.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 280-nm detector and a 4.6-mm × 25-cm column that contains base-deactivated packing L1. The flow rate is about 1 mL per minute. The column temperature is maintained at 40
. The chromatograph is programmed as follows.
Time (minutes) |
Solution A
(%) |
Solution B
(%) |
Elution |
0 |
70 |
30 |
equilibration |
035 |
70®0 |
30®100 |
linear gradient |
Chromatograph
Standard solution 1, and record the peak responses as directed for
Procedure: the column efficiency is not less than 10,000 theoretical plates; the tailing factor is not more than 1.5; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 10 µL) of Standard solution 1, Standard solution 2, the Test solution, and a methanol blank into the chromatograph, record the chromatograms, and measure all of the peak responses. Disregard the contributions due to any peaks found in the methanol blank. The sum of the peak responses, excluding that of pergolide, from the Test solution is not more than the pergolide peak response obtained from Standard solution 1 (0.5%), and no single peak response is more than the pergolide peak response obtained from Standard solution 2 (0.1%).
Assay
Diluent
Dissolve 5 mg of methionine in 500 mL of 0.01 N hydrochloric acid. Add 500 mL of methanol, and mix.
Mobile phase
Prepare a solution of 0.009 M sodium 1-octanesulfonate containing 1.0 mL of glacial acetic acid per L. Prepare a filtered and degassed mixture of this solution, methanol, and acetonitrile (2:1:1). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard preparation
Dissolve an accurately weighed quantity of
USP Pergolide Mesylate RS in
Diluent, and dilute quantitatively, and stepwise if necessary, with
Diluent to obtain a solution having a known concentration of about 0.13 mg per mL.
Assay preparation
Transfer about 6.5 mg of Pergolide Mesylate, accurately weighed, to a 50-mL volumetric flask, dissolve in and dilute with Diluent to volume, and mix.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 280-nm detector and a 4.6-mm × 25-cm column that contains base-deactivated packing L7. The flow rate is about 1 mL per minute. The column temperature is maintained at 40
. Chromatograph the
Resolution solution, and record the peak responses as directed for
Procedure: the resolution,
R, between pergolide sulfoxide and pergolide is not less than 12.0. Chromatograph the
Standard preparation, and record the peak responses as directed for
Procedure: the tailing factor is not more than 1.5; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 10 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the pergolide peaks. Calculate the quantity, in mg, of C
19H
26N
2S·CH
4O
3S in the portion of Pergolide Mesylate taken by the formula:
50C(rU / rS),
in which
C is the concentration, in mg per mL, of
USP Pergolide Mesylate RS in the
Standard preparation; and
rU and
rS are the peak responses obtained from the
Assay preparation and the
Standard preparation, respectively.