Identification, Ultraviolet Absorption 197U
Solution:
Sonicate a weighed portion of ground Tablets in sufficient methanol to obtain a solution containing about 0.4 mg of penbutolol sulfate per mL. Filter this solution, and dilute a portion of the filtrate with methanol to obtain a solution containing about 0.06 mg of penbutolol sulfate per mL.
Dissolution 711
Medium:
water; 900 mL.
Apparatus 2:
50 rpm.
Time:
30 minutes.
Mobile phase
Dissolve 2 g of ammonium acetate in 250 mL of water, add 750 mL of acetonitrile, mix, and adjust with glacial acetic acid to a pH of 6.0. Filter and degas. Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard solution
Dissolve an accurately weighed quantity of
USP Penbutolol Sulfate RS quantitatively in water to obtain a stock solution having a known concentration of about 0.018 mg per mL. Mix 10.0 mL of this solution and 10.0 mL of acetonitrile, and filter through a filter having a 0.5-µm or finer porosity.
Test solution
Filter about 30 mL of the solution under test. Mix 10.0 mL of the filtrate and 10.0 mL of acetonitrile, and filter through a filter having a 0.5-µm or finer porosity.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 272-nm detector, a 4.6-mm × 15-cm column that contains 5-µm diameter packing L10. The flow rate is about 2.5 mL per minute. Chromatograph the
Standard solution, and record the peak responses as directed for
Procedure: the relative standard deviation for replicate injections is not more than 2.5%.
Procedure
Separately inject equal volumes (about 50 µL) of the
Standard solution and the
Test solution into the chromatograph, and measure the areas of the responses for the penbutolol peaks. Calculate the quantity, in mg, of (C
18H
29NO
2)
2·H
2SO
4 dissolved by the formula:
1800C(rU / rS),
in which
C is the concentration, in mg per mL, of
USP Penbutolol Sulfate RS in the
Standard solution, and
rU and
rS are the penbutolol peak responses obtained from the
Test solution and the
Standard solution, respectively.
Tolerances
Not less than 75% (Q) of the labeled amount of (C18H29NO2)2·H2SO4 is dissolved in 30 minutes.
Chromatographic purity
Examine the chromatogram of the
Assay preparation obtained in the
Assay. If an impurity peak is observed at a retention time of 0.8 relative to that of penbutolol, calculate the percentage of that impurity by the formula:
100ri / rs,
in which
ri is the response of the impurity peak, and
rs is the sum of the responses of all of the peaks. If the percentage exceeds 1.2%, perform the following test.
Test solution
Transfer an accurately weighed portion of powdered Tablets, equivalent to about 100 mg of penbutolol sulfate, to a 50-mL volumetric flask, dilute with Solvent mixture to volume, mix, and filter.
Diluted test solution
Transfer 1.0 mL of the Test solution to a 100-mL volumetric flask, dilute with Solvent mixture to volume, and mix.
Procedure
Proceed as directed for
Procedure in the test for
Chromatographic purity under
Penbutolol Sulfate. Calculate the percentage of each individual impurity in the portion of Tablets taken by the formula:
ri / rD,
in which the terms are as defined therein: not more than 1.2% of any impurity is found.
Assay
Standard preparation
Dissolve an accurately weighed quantity of
USP Penbutolol Sulfate RS quantitatively in
Mobile phase to obtain a solution having a known concentration of about 0.2 mg per mL.
Resolution solution
Prepare a solution of 3,4-dimethylbenzophenone in Standard preparation containing about 0.01 mg of 3,4-dimethylbenzophenone per mL.
Assay preparation
Weigh and finely powder not less than 20 Tablets. Transfer an accurately weighed portion of the powder, equivalent to about 20 mg of penbutolol sulfate, to a 100-mL volumetric flask, dilute with
Mobile phase to volume, and mix. Sonicate for about 10 minutes, and filter a portion through a filter having a 0.5-µm or finer porosity, discarding the first 5 mL of the filtrate. Use the clear filtrate as the
Assay preparation.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 270-nm detector and a 4.6-mm × 15-cm column that contains 5-µm diameter packing L1. The flow rate is about 1 mL per minute. Chromatograph the
Resolution solution, and record the peak responses as directed for
Procedure: the relative retention times are about 0.7 for penbutolol and 1.0 for 3,4-dimethylbenzophenone, and the tailing factor is not more than 1.4, when calculated by the formula:
W0.1 / 2f,
in which
W0.1 is the width of the peak at 10% of peak height, the resolution,
R, between the penbutolol peak and the 3,4-dimethylbenzophenone peak is not less than 5, and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
[NOTEUse peak areas where peak responses are indicated.
] Separately inject equal volumes (about 20 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of (C
18H
29NO
2)
2·H
2SO
4 in the portion of Tablets taken by the formula:
100C(rU / rS),
in which
C is the concentration, in mg per mL, of
USP Penbutolol Sulfate RS in the
Standard preparation, and
rU and
rS are the penbutolol peak responses obtained from the
Assay preparation and the