Assay
Mobile phase
Prepare a solution of sodium acetate in water containing 2.5 mg per mL, and adjust with glacial acetic acid to a pH of 4.75 ± 0.1. Prepare a mixture of this solution and acetonitrile (800:225). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
System suitability solution
Prepare a solution in
Mobile phase containing in each mL about 1.2 µg of methylparaben, 12 µg of sulfabenzamide, and 72 µg of
USP Oxfendazole RS.
Internal standard solution
Prepare a solution of sulfabenzamide in Mobile phase containing about 0.3 mg per mL.
Standard preparation
Prepare a solution of
USP Oxfendazole RS in methanol having a known concentration of about 900 µg per mL. Transfer 20.0 mL of this solution to a 100-mL volumetric flask, add 4.0 mL of
Internal standard solution, dilute with
Mobile phase to volume, and mix. This solution contains about 180 µg of
USP Oxfendazole RS per mL.
Assay preparation
Transfer an accurately measured volume of the Suspension, previously well-mixed and free from air bubbles, equivalent to about 450 mg of oxfendazole, to a 500-mL volumetric flask. Add about 30 mL of water, and swirl to disperse. Add about 300 mL of methanol, and dissolve with the aid of sonication. Transfer 20.0 mL of this solution to a 100-mL volumetric flask, add 4.0 mL of
Internal standard solution, dilute with
Mobile phase to volume, and mix.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 254-nm detector, a guard column containing packing L2, and a 4.6-mm × 25-cm analytical column that contains packing L1. The flow rate is about 1 mL per minute. Chromatograph the
System suitability solution, and record the peak responses as directed for
Procedure: the relative retention times are about 0.7 for sulfabenzamide, 0.8 for methylparaben, and 1.0 for oxfendazole; the resolution,
R, between the methylparaben peak and the oxfendazole peak is not less than 2.0; the column efficiency determined from the oxfendazole peak is not less than 2000 theoretical plates; and the relative standard deviation of replicate injections is not more than 1.5%.
[NOTEThe detector sensitivity may be changed between the peaks to keep the responses on scale.
]
Procedure
Separately inject equal volumes (about 50 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, and measure the responses for the major peaks. Calculate the quantity, in mg, of oxfendazole (C
15H
13N
3O
3S) in each mL of the Suspension taken by the formula:
2.5(C / V)(RU / RS),
in which
C is the concentration, in µg per mL, of
USP Oxfendazole RS in the
Standard preparation; V is the volume, in mL, of Suspension taken to prepare the
Assay preparation; and
RU and
RS are the ratios of the oxfendazole peak response to the sulfabenzamide peak response obtained from the
Assay preparation and the
Standard preparation, respectively.