Assay
0.05 M Phosphate buffer
Dissolve 6.805 g of monobasic potassium phosphate in 1000 mL of water.
Mobile phase
Prepare a filtered and degassed mixture of acetonitrile and
0.05 M Phosphate buffer (65:35). Adjust with phosphoric acid to a pH of 4.7, and mix. Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard preparation
Dissolve an accurately weighed quantity of
USP Levocarnitine RS in water to obtain a solution having a known concentration of about 10 mg per mL.
Assay preparation
Pool the contents of ten containers, and dilute an accurately measured volume of Injection quantitatively with water to obtain a solution having a concentration of about 10 mg of levocarnitine per mL.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 205-nm detector and a 3.9-mm × 30-cm column that contains packing L8. The flow rate is maintained at about 1 mL per minute. The system is programmed to provide variable mixtures of acetonitrile,
Mobile phase, and water. Initially elute 50 mL of acetonitrile, then change the composition linearly over the next 20 minutes to a mixture of 65% acetonitrile and 35% water. Elute 100 mL of this mixture, then change the composition linearly over the following 20 minutes to 100%
Mobile phase, and allow the chromatograph to proceed for about 3 hours. Chromatograph the
System suitability solution, and record the peak responses as directed for
Procedure: the resolution,
R, between levocarnitine related compound A and levocarnitine is not less than 1.0; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 5 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of levocarnitine (C
7H
15NO
3) in the portion of Injection taken by the formula:
(CL / D)(rU / rS),
in which
C is the concentration, in mg per mL, of
USP Levocarnitine RS in the
Standard preparation; L is the labeled quantity, in mg, of levocarnitine in each container;
D is the concentration, in mg per mL, of levocarnitine in the
Assay preparation, based on the labeled quantity per container and the extent of dilution; and
rU and
rS are the levocarnitine peak responses obtained from the
Assay preparation and the
Standard preparation, respectively.