Limit of azide
Mobile phase
Prepare a filtered and degassed 0.1 N sodium hydroxide solution (see
System Suitability under
Chromatography 621).
Standard solution
Transfer about 25 mg of sodium azide, accurately weighed, to a 100-mL volumetric flask, dissolve in and dilute with Mobile phase to volume, and mix. Pipet 250 µL of this solution into a 200-mL volumetric flask, dilute with Mobile phase to volume, and mix. This solution contains about 0.312 µg of sodium azide per mL.
Test solution
Transfer about 100 mg of Irbesartan, accurately weighed, to a 5-mL volumetric flask, dissolve in and dilute with Mobile phase to volume, and mix.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a conductimetric detector, and a 4.0-mm × 25-cm column that contains packing L46. The flow rate is about 1.0 mL per minute. Chromatograph the
Standard solution, and record the peak responses as directed for
Procedure: the signal to noise ratio for the azide peak is not less than 10.
Procedure
Separately inject equal volumes (about 200 µL) of the
Standard solution and the
Test solution into the chromatograph, record the chromatograms, and measure the peak area for azide peak. Calculate the amount of azide in ppm in the portion of Irbesartan taken by the formula:
1000(CS / CT)(42.02/65.01)(rU / rS),
in which
CS is the concentration, in µg per mL, of sodium azide in the
Standard solution; CT is the concentration, in mg per mL, of Irbesartan in the
Test solution; rU is the peak area for azide obtained from the
Test solution; and
rS is the peak area for azide obtained from the
Standard solution: not more than 10 ppm of azide is found.
Related compounds
pH 3.2 Phosphate buffer, Mobile phase, and Dilute standard solution
Proceed as directed in the Assay.
Standard solution
Prepare as directed for the System suitability solution in the Assay.
Chromatographic system (see Chromatography 621)
Proceed as directed in the
Assay. Chromatograph the
Standard solution and record the peak responses as directed for
Procedure: the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 10 µL) of the
Standard solution and the
Test solution into the chromatograph, record the chromatograms, and measure the area for irbesartan related compound A peak. Calculate the percentage of irbesartan related compound A in the portion of Irbesartan taken by the formula:
100(CS / CT)(rU / rS),
in which
CS is the concentration, in mg per mL, of USP Irbesartan Related Compound A RS in the
Standard solution; CT is the concentration, in mg per mL, of Irbesartan in the
Test solution; rU is the peak response for irbesartan related compound A obtained from the
Test solution; and
rS is the peak response for irbesartan related compound A obtained from the
Standard solution: not more than 0.2% of irbesartan related compound A is found, not more than 0.1% of any other impurity is found; and not more than 0.5% of total impurities is found.
Assay
pH 3.2 Phosphate buffer
Mix 5.5 mL of phosphoric acid with about 950 mL of water, and adjust pH to 3.2 with triethylamine.
Mobile phase
Prepare a filtered and degassed mixture of pH 3.2 phosphate buffer and acetonitrile (67:33). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
System suitability solution
Dissolve accurately weighed quantities of
USP Irbesartan RS and USP Irbesartan Related Compound A RS in methanol to obtain a solution having a known concentration of about 0.05 mg per mL of each USP Reference Standard.
Dilute standard solution
Dissolve an accurately weighed quantity of
USP Irbesartan RS in methanol to obtain a solution having a known concentration of about 1 µg per mL.
Standard preparation
Dissolve an accurately weighed quantity of
USP Irbesartan RS in methanol to obtain a solution having a known concentration of about 0.5 mg per mL.
Assay preparation
Transfer about 50 mg of Irbesartan, accurately weighed, to a 100-mL volumetric flask, dissolve in and dilute with methanol to volume, and mix.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 220-nm detector and a 4.0-mm × 25-cm column that contains packing L1. The flow rate is about 1.0 mL per minute. Chromatograph the
System suitability solution, and record the peak responses as directed for
Procedure: the relative retention times are about 0.8 for irbesartan related compound A and 1.0 for irbesartan; the resolution,
R, between irbesartan and irbesartan related compound A is not less than 2.0. Chromatograph the
Standard preparation, and record the peak response as directed for
Procedure: the standard deviation for replicate injections is not more than 1.0%.
Procedure
Separately inject equal volumes (about 10 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for all the peaks. Calculate the quantity, in mg, of C
25H
28N
6O in the portion of Irbesartan taken by the formula:
100C(rU / rS),
in which
C is the concentration, in mg per mL, of
USP Irbesartan RS in the
Standard preparation; and
rU and
rS are the peak responses obtained from the
Assay preparation and the