Identification
A:
Triturate a quantity of finely powdered Tablets, equivalent to about 100 mg of guaifenesin, with 10 mL of chloroform, filter, and evaporate 1 mL of the filtrate on a watch glass. Mix the residue with 1 drop of formaldehyde and a few drops of sulfuric acid: a deep cherry-red to purple color is produced.
B:
The retention time of the guaifenesin peak in the chromatogram of the
Assay preparation corresponds to that of the guaifenesin peak in the chromatogram of the
Standard preparation as obtained in the
Assay.
Assay
Mobile phase
Prepare a suitable filtered and degassed mixture of water, methanol, and glacial acetic acid (60:40:1.5). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Benzoic acid solution
Dissolve a suitable quantity of benzoic acid in methanol to obtain a solution containing about 2 mg per mL.
Resolution solution
Dissolve a suitable quantity of guaifenesin in water, with shaking, to obtain a solution containing about 2 mg per mL. Transfer 2.0 mL of this solution and 5.0 mL of Benzoic acid solution to a 100-mL volumetric flask, add 40 mL of methanol, dilute with water to volume, and mix to obtain a solution containing about 40 µg of guaifenesin and 100 µg of benzoic acid per mL.
Standard preparation
Dissolve an accurately weighed quantity of
USP Guaifenesin RS quantitatively in water, with shaking, to obtain a solution having a known concentration of about 2 mg per mL. Transfer 2.0 mL of this solution to a 100-mL volumetric flask, add 45 mL of methanol, dilute with water to volume, and mix to obtain a
Standard preparation having a known concentration of about 40 µg per mL.
Assay preparation
Weigh and finely powder not less than 20 Tablets. Transfer an accurately weighed portion of the powder, equivalent to about 200 mg of guaifenesin, to a 100-mL volumetric flask, add about 60 mL of water, and shake for about 15 minutes. Dilute with water to volume, filter if necessary to obtain a clear solution, and mix. Transfer 2.0 mL of this solution to a 100-mL volumetric flask, add 45 mL of methanol, dilute with water to volume, and mix.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 276-nm detector and a 4.6-mm × 25-cm column that contains 10-µm packing L1. The flow rate is about 2 mL per minute. Chromatograph the
Resolution solution, and record the peak responses as directed under
Procedure: the resolution,
R, between the guaifenesin and benzoic acid peaks is not less than 3.0 (the relative retention times are about 0.7 for guaifenesin and 1.0 for benzoic acid). Chromatograph the
Standard preparation, and record the peak responses as directed under
Procedure: the relative standard deviation for replicate injections is not more than 2.5%.
Procedure
Separately inject equal volumes (about 20 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of guaifenesin (C
10H
14O
4) in the portion of Tablets taken by the formula:
5C(rU / rS),
in which
C is the concentration, in µg per mL, of
USP Guaifenesin RS in the
Standard preparation, and
rU and
rS are the peak responses obtained from the
Assay preparation and the
Standard preparation, respectively.