Identification
Test specimen
Transfer a quantity of finely powdered Tablets, equivalent to about 50 mg of cyclobenzaprine hydrochloride, to a small flask, add 10 mL of methylene chloride, swirl to dissolve, and filter. Evaporate the clear filtrate to about 5 mL, transfer to a suitable centrifuge tube, and add 1 to 2 mL of ether. Evaporate with the aid of a current of air to about 1 mL, and agitate until crystallization occurs. Wash the crystals with several portions of ether, and air-dry.
B:
The retention time of the major peak in the chromatogram of the
Assay preparation corresponds to that in the chromatogram of the
Standard preparation, as obtained in the
Assay.
Dissolution 711
Medium:
0.1 N hydrochloric acid; 900 mL.
Apparatus 1:
50 rpm.
Time:
30 minutes.
Procedure
Determine the amount of C
20H
21N·HCl dissolved by employing UV absorption at the wavelength of maximum absorbance at about 290 nm on filtered portions of the solution under test, suitably diluted with
Dissolution Medium, if necessary, in comparison with a Standard solution having a known concentration of
USP Cyclobenzaprine Hydrochloride RS in the same
Medium.
Tolerances
Not less than 75% (Q) of the labeled amount of C20H21N·HCl is dissolved in 30 minutes.
Assay
Mobile phase
Prepare a suitable filtered and degassed mixture of water, acetonitrile, methanol, and methanesulfonic acid (48:28:24:0.2), and adjust with diethylamine to a pH of 3.6. Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard preparation
Dissolve an accurately weighed quantity of
USP Cyclobenzaprine Hydrochloride RS in 0.1 N hydrochloric acid, and dilute quantitatively, and stepwise if necessary, with 0.1 N hydrochloric acid to obtain a solution having a known concentration of about 0.05 mg per mL.
Assay preparation
Weigh and finely powder not fewer than 20 Tablets. Transfer an accurately weighed portion of the powder, equivalent to about 10 mg of cyclobenzaprine hydrochloride, to a 200-mL volumetric flask, add 150 mL of 0.1 N hydrochloric acid, and shake by mechanical means for 30 minutes. Dilute with 0.1 N hydrochloric acid to volume, mix, and filter.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 290-nm detector and a 4.6-mm × 10-cm column that contains packing L1. The flow rate is about 1.5 mL per minute. Chromatograph the
Standard preparation, and record the peak responses as directed for
Procedure: the capacity factor,
k¢, for the analyte peak is not less than 2.0; the column efficiency determined from the analyte peak is not less than 1000 theoretical plates; the tailing factor for the analyte peak is not more than 2; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 10 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the areas for the major peaks. Calculate the quantity, in mg, of C
20H
21N·HCl in the portion of Tablets taken by the formula:
200C(rU / rS),
in which
C is the concentration, in mg per mL, of
USP Cyclobenzaprine Hydrochloride RS in the
Standard preparation: and
rU and
rS are the peak responses obtained from the
Assay preparation and the