Identification
A:
Transfer a quantity of Ophthalmic Ointment, equivalent to about 20 mg of chloramphenicol, to a screw-capped test tube, add 5 mL of 5 N sodium hydroxide and 2 mL of pyridine, and shake. Place the tube in a water bath at 50
for 20 minutes: a reddish brown color develops in the pyridine layer.
B:
The retention time of the major peak in the chromatogram of the
Assay preparation corresponds to that in the chromatogram of the
Standard preparation as obtained in the
Assay for chloramphenicol.
C:
Transfer a quantity of Ophthalmic Ointment, equivalent to about 1.5 mg of prednisolone, to a screw-capped test tube, add 10 mL of methylene chloride, and shake to disperse. Heat at 60
for 15 minutes, and allow to cool while shaking for about 30 minutes. Allow to separate, draw off the upper ointment layer, and retain the lower methylene chloride layer. Apply, in portions, 0.4 mL each of the methylene chloride test solution and a Standard solution of
USP Prednisolone RS in chloroform containing 0.5 mg per mL to a suitable thin-layer chromatographic plate (see
Chromatography 621), coated with a 0.25-mm layer of chromatographic silica gel mixture. Allow each portion to dry before adding the next portion to the same spot. Develop the chromatogram in a chromatographic chamber lined with paper and equilibrated with a solvent system consisting of a mixture of chloroform and acetone (4:1) until the solvent front has moved about three-fourths of the length of the plate. Remove the plate from the developing chamber, mark the solvent front, and allow the solvent to evaporate. Locate the spots on the plate by examination under short-wavelength UV light: the
RF value of the principal spot obtained from the
Test solution corresponds to that obtained from the
Standard solution.
Assay for chloramphenicol
Standard preparation
Dissolve an accurately weighed quantity of
USP Chloramphenicol RS in
Methanol-water solution to obtain a solution having a known concentration of about 0.3 mg per mL.
Assay preparation
Transfer an accurately weighed portion of Ophthalmic Ointment, equivalent to about 3.0 mg of chloramphenicol, to a screw-capped test tube. Add 10 mL of n-heptane, and shake by mechanical means until the substance is dissolved. Add 10.0 mL of Methanol-water solution, and shake by mechanical means for 30 seconds. Allow the layers to separate, and carefully remove the upper phase. Centrifuge the lower phase for 15 minutes, and use the clear portion as the Assay preparation.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 280-nm detector and a 3.9-mm × 30-cm column that contains packing L1. The flow rate is about 1 mL per minute. Chromatograph the
Standard preparation, and record the peak responses as directed under
Procedure: the peak for chloramphenicol obtained from the Ophthalmic Ointment, at a retention time corresponding to that of the peak obtained from the Reference Standard, exhibits baseline separation from the adjacent prednisolone peak, and the relative standard deviation of replicate injections is not more than 1.5%.
Procedure
Separately inject equal volumes (about 20 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of C
11H
12Cl
2N
2O
5 in the portion of Ophthalmic Ointment taken by the formula:
10C(rU / rS),
in which
C is the concentration, in mg per mL, of
USP Chloramphenicol RS in the
Standard preparation; and
rU and
rS are the peak responses obtained from the
Assay preparation and the
Standard preparation, respectively.
Assay for prednisolone
Methanol-water solution
Mix 4 volumes of methanol with 1 volume of water, and mix.
Mobile phase
Dissolve 0.68 g of sodium acetate trihydrate in 400 mL of water in a 1000-mL graduated cylinder, adjust with glacial acetic acid to a pH of 4.0, and dilute with water to 500 mL. Dilute with methanol to 1000 mL, and mix. Filter this solution through a membrane filter (1 µm or finer porosity), and degas. Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard preparation
Dissolve an accurately weighed quantity of
USP Prednisolone RS in
Methanol-water solution to obtain a solution having a known concentration of about 0.2 mg per mL.
Assay preparation
Transfer an accurately weighed portion of Ophthalmic Ointment, equivalent to about 2.0 mg of Prednisolone, to a screw-capped test tube. Add 10 mL of n-heptane, and shake by mechanical means until the substance is dissolved. Add 10.0 mL of Methanol-water solution, and shake by mechanical means for 30 seconds. Allow the layers to separate, and carefully remove the upper phase. Centrifuge the lower phase for 15 minutes, and use the clear portion as the Assay preparation.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 254-nm detector and a 3.9-mm × 30-cm column that contains packing L1. The flow rate is about 1.5 mL per minute. Chromatograph the
Standard preparation, and record the peak responses as directed under
Procedure: the peak for prednisolone obtained from the Ophthalmic Ointment, at a retention time corresponding to that of the peak obtained from the
Reference Standard, exhibits baseline separation from the adjacent chloramphenicol peak, and the relative standard deviation of replicate injections is not more than 1.5%.
Procedure
Separately inject equal volumes (about 15 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of C
21H
28O
5 in the portion of Ophthalmic Ointment taken by the formula:
10C(rU / rS),
in which
C is the concentration, in mg per mL, of
USP Prednisolone RS in the
Standard preparation; and
rU and
rS are the peak responses obtained from the
Assay preparation and the