Limit of N-methylpyrrolidine
Mobile phase
Prepare a filtered and degassed mixture of 0.01 N nitric acid and acetonitrile (100:1). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard solution
Transfer about 0.16 mL of N-methylpyrrolidine, accurately weighed, to a 100-mL volumetric flask, dissolve in and dilute with water to volume, and mix. Transfer 4.0 mL of this solution to a 100-mL volumetric flask, dilute with 0.01 N nitric acid to volume, and mix. This solution contains about 0.05 mg of N-methylpyrrolidine per mL.
Test solution
Transfer about 100 mg of Cefepime Hydrochloride, accurately weighed, to a 10-mL volumetric flask, dissolve in and dilute with 0.01 N nitric acid to volume, and mix. [NOTEUse this solution within 30 minutes.]
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a conductivity detector and a 4.6-mm × 5-cm column that contains 5-µm packing L52. The flow rate is about 1 mL per minute. Chromatograph the
Standard solution, and record the peak responses as directed for
Procedure: the retention time of
N-methylpyrrolidine is not less than 8 minutes, and the relative standard deviation for replicate injections is not more than 5.0%.
Procedure
Separately inject equal volumes (about 100 µL) of the
Standard solution and the
Test solution into the chromatograph, record the chromatograms, and measure the peak responses for
N-methylpyrrolidine. Calculate the percentage of
N-methylpyrrolidine in the portion of Cefepime Hydrochloride taken by the formula:
1000(C/W)(rU / rS),
in which
C is the concentration, in mg per mL, of
N-methylpyrrolidine in the
Standard solution; W is the quantity, in mg, of Cefepime Hydrochloride taken to prepare the
Test solution; and
rU and
rS are the
N-methylpyrrolidine peak responses obtained from the
Test solution and the
Standard solution, respectively: not more than 0.3% is found.
Related compounds
Potassium phosphate solution
Dissolve 0.68 g of monobasic potassium phosphate in 1000 mL of water.
Solution A
Prepare a mixture of Potassium phosphate solution and acetonitrile (9:1). Adjust with a potassium hydroxide solution (2 in 100) to a pH of 5.0, filter, and degas.
Solution B
Prepare a mixture of Potassium phosphate solution and acetonitrile (1:1). Adjust with a potassium hydroxide solution (2 in 100) to a pH of 5.0, filter, and degas.
Mobile phase
Use variable mixtures of
Solution A and
Solution B as directed for
Chromatographic system. Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Test solution
Transfer about 70 mg of Cefepime Hydrochloride, accurately weighed, to a 50-mL volumetric flask, dissolve in and dilute with Solution A to volume, sonicate, and mix. [NOTEInject this solution immediately, or store in a refrigerator and inject within 12 hours.]
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 254-nm detector and a 4.6-mm × 25-cm column that contains 5-µm packing L1. The flow rate is about 1 mL per minute. The chromatograph is programmed as follows.
Time (minutes) |
Solution A
(%) |
Solution B
(%) |
Elution |
010 |
100 |
0 |
isocratic |
1030 |
100®50 |
0®50 |
linear gradient |
3035 |
50 |
50 |
isocratic |
3536 |
50®100 |
50®0 |
linear gradient |
Chromatograph the
System suitability solution, and record the peak responses as directed for
Procedure: the relative retention times are about 2.7 for cefepime related compound A, 4.3 for cefepime related compound B, and 1.0 for cefepime; and the resolution,
R, between cefepime and cefepime related compound A is not less than 5 and between cefepime related compound A and cefepime related compound B is not less than 10. Chromatograph the
Test solution, and record the peak responses as directed for
Procedure: the capacity factor,
k¢, is more than 0.6; the column efficiency is not less than 4000 theoretical plates; and the tailing factor is not more than 1.1.
Procedure
Inject a volume (about 10 µL) of the
Test solution into the chromatograph, record the chromatogram, and measure the peak responses. Calculate the percentage of each impurity in the portion of Cefepime Hydrochloride taken by the formula:
100(ri / rs),
in which
ri is the peak response for each impurity; and
rs is the sum of the responses for all the peaks: not more than 0.3% of cefepime related compound A is found; not more than 0.2% of cefepime related compound B is found; and not more than 0.1% of any other impurity is found.
Assay
Mobile phase
Dissolve 5.76 g of sodium 1-pentanesulfonate in 2000 mL of water. Adjust with glacial acetic acid to a pH of 3.4, and then with
potassium hydroxide TS to a pH of 4.0. Prepare a filtered and degassed mixture of this solution and acetonitrile (94:6). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard preparation
Dissolve an accurately weighed quantity of
USP Cefepime Hydrochloride RS in
Mobile phase to obtain a solution having a known concentration of about 1.4 mg per mL.
Assay preparation
Transfer about 70 mg of Cefepime Hydrochloride, accurately weighed, to a 50-mL volumetric flask, dissolve in and dilute with Mobile phase to volume, and mix.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 254-nm detector and a 3.9-mm × 30-cm column that contains packing L1. The flow rate is about 2 mL per minute. Chromatograph the
Standard preparation, and record the peak responses as directed for
Procedure: the column efficiency is not less than 1500 theoretical plates; the tailing factor is not more than 1.7; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 10 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in µg, of cefepime (C
19H
24N
6O
5S
2) in each mg of Cefepime Hydrochloride taken by the formula:
50(CP/W)(rU/rS),
in which
C is the concentration, in mg per mL, of
USP Cefepime Hydrochloride RS in the
Standard preparation; P is the content, in µg per mg, of cefepime in
USP Cefepime Hydrochloride RS;
W is the weight, in mg, of Cefepime Hydrochloride taken to prepare the
Assay preparation; and
rU and
rS are the peak responses obtained from the
Assay preparation and the
Standard preparation, respectively.