Identification
B: 
Dissolve about 50 mg in 2 mL of water, add 0.1 mL of cobaltous chloride solution (1 in 100), then add 0.1 mL of 
potassium ferrocyanide TS: an emerald-green color is produced, and almost entirely fades in 5 to 10 minutes
 (distinction from choline chloride, which gives the same reaction but the color does not fade).
 
C: 
To 1 mL of a solution (1 in 100) add 0.1 mL of iodine TS: a brown precipitate is formed, and it rapidly changes to a dark olive-green color.
D: 
A solution of it responds to the tests for 
Chloride 
191
.
 
 
Chloride content
Dissolve about 400 mg, previously dried and accurately weighed, in 30 mL of water. Add 40.0 mL of 0.1 N silver nitrate VS, then add 3 mL of nitric acid and 5 mL of nitrobenzene, shake for a few minutes, add 2 mL of 
ferric ammonium sulfate TS, and titrate the excess silver nitrate with 0.1 N ammonium thiocyanate VS. Each mL of 0.1 N silver nitrate is equivalent to 3.545 mg of Cl: the content of Cl is between 17.7% and 18.3%.
 
Related compounds
Buffer solution
Transfer about 0.48 g of methanesulfonic acid to a 1000-mL volumetric flask. Dissolve in and dilute with water to volume.
Mobile phase
Prepare a filtered and degassed mixture of 
Buffer solution and acetonitrile (95:5). Make adjustments if necessary (see 
System Suitability under 
Chromatography 
621
).
 
Standard solution
Dissolve an accurately weighed quantity of 
USP Bethanechol Chloride RS in 
Mobile phase, and dilute quantitatively, and stepwise if necessary, with 
Mobile phase to obtain a solution having a known concentration of about 1 µg of 
USP Bethanechol Chloride RS per mL.
 
Test solution
Transfer about 25 mg of Bethanechol Chloride, accurately weighed, to a 250-mL volumetric flask. Dissolve in and dilute with Mobile phase to volume, and mix.
System suitability solution
Transfer about 25 mg of Bethanechol Chloride, accurately weighed, to a 250-mL volumetric flask. Add 10 mL of 0.1 N sodium hydroxide, and allow to stand for about 15 minutes. Add 10 mL of 0.1 N hydrochloric acid. Dissolve in and dilute with Mobile phase to volume, and mix.
Chromatography system (see Chromatography 
621
)
The liquid chromatograph is equipped with a conductivity detector and a 3.9- × 150-mm column containing packing L55. The flow rate is about 1.0 mL per minute. The detector and column temperatures are maintained at 35

 and 30

, respectively. Chromatograph the 
System suitability solution, and record the peak responses as directed for 
Procedure: the relative retention time is about 0.9 for 2-hydroxypropyltrimethyl ammonium chloride and 1.0 for bethanechol; the resolution, 
R, between 2-hydroxypropyltrimethyl ammonium chloride and bethanechol is not less than 0.8. Chromatograph the 
Standard solution, and record the peak responses as directed for 
Procedure: the relative standard deviation for replicate injections is not more than 10.0% for bethanechol chloride.
 
Procedure
Separately inject equal volumes (about 50 µL) of the 
Mobile phase, the 
Standard solution, and the 
Test solution into the chromatograph, record the chromatograms, and measure the peak responses for all the peaks. Calculate the percentage of each impurity in the portion of Bethanechol Chloride taken by the formula: 
25,000C(F/W)(ri / rS),
in which 
C is the concentration, in mg per mL, of 
USP Bethanechol Chloride RS in the 
Standard solution; F is the relative response factor and is equal to 0.79 for 2-hydroxypropyltrimethyl ammonium and 1.0 for any other impurity; 
W is the weight, in mg, of Bethanechol Chloride taken to prepare the 
Test solution; ri is the peak response for any impurity in the 
Test solution; and 
rS is the peak response of 
USP Bethanechol Chloride RS in the 
Standard solution. Not more than 1.0% of 2-hydroxypropyltrimethyl ammonium is found; not more than 0.1% of any other impurity is found; and the sum of all the impurities is not more than 1.5%.
 
 
Assay
Buffer solution
Transfer about 29 mg of edetic acid to a 1000-mL volumetric flask, and dissolve in 500 mL of water. Add 300 µL of nitric acid to the volumetric flask, and dilute with water to volume. Pass through a 0.45-µm nylon membrane filter.
Mobile phase
Prepare a filtered and degassed mixture of 
Buffer solution and acetonitrile (95:5). Make adjustments if necessary (see 
System Suitability under 
Chromatography 
621
).
 
System suitability solution
Transfer about 25 mg of Bethanechol Chloride, accurately weighed, to a 250-mL volumetric flask. Add 10 mL of 0.1 N sodium hydroxide, and allow to stand for about 15 minutes. Add 10 mL of 0.1 N hydrochloric acid. Dissolve in and dilute with Mobile phase to volume, and mix.
Standard preparation
Dissolve an accurately weighed quantity of 
USP Bethanechol Chloride RS in 
Mobile phase, and dilute quantitatively, and stepwise if necessary, with 
Mobile phase to obtain a solution having a known concentration of about 0.1 mg of 
USP Bethanechol Chloride RS per mL.
 
Assay preparation
Transfer about 25 mg of Bethanechol Chloride, accurately weighed, to a 250-mL volumetric flask. Dissolve in and dilute with Mobile phase to volume, and mix.
Chromatographic system (see Chromatography 
621
)
The liquid chromatograph is equipped with a conductivity detector and a 3.9- × 150-mm column containing packing L55. The flow rate is about 1.0 mL per minute. The detector and column temperatures are maintained at 35

 and 30

, respectively. Chromatograph the 
System suitability solution, and record the peak responses as directed for 
Procedure: the relative retention times are about 0.9 for 2-hydroxypropyltrimethyl ammonium chloride and 1.0 for bethanechol; and the resolution, 
R, between 2-hydroxypropyltrimethyl ammonium chloride and bethanechol is not less than 0.8. Chromatograph the 
Standard preparation, and record the peak responses as directed for 
Procedure: the tailing factor is not more than 3.5; and the relative standard deviation for replicate injections is not more than 3.0%.
 
Procedure
Separately inject equal volumes (about 25 µL) of the 
Standard preparation and the 
Assay preparation into the chromatograph, record the chromatograms, and measure the peak responses. Calculate the quantity, in mg, of C
7H
17ClN
2O
2 in the portion of Bethanechol Chloride taken by the formula: 
250C(rU / rS),
in which 
C is the concentration, in mg per mL, of 
USP Bethanechol Chloride RS in the 
Standard preparation; and 
rU and 
rS are the bethanechol chloride peak responses obtained from the 
Assay preparation and the 
Standard preparation, respectively.