Limit of free salicylic acid
Adsorbent:
0.25-mm layer of chromatographic silica gel mixture.
Test solution
Transfer about 48 mg of Trolamine Salicylate, accurately weighed, to a 50-mL volumetric flask, dilute with xylene to volume, and mix.
Standard solution 1
Dissolve an accurately weighed quantity of
USP Salicylic Acid RS in xylene, and dilute quantitatively, and stepwise if necessary, with xylene to obtain a solution having a known concentration of about 0.2 mg per mL.
Standard solution 2
Dilute an accurately measured quantity of Standard solution 1 in xylene to obtain a solution having a known concentration of about 0.1 mg per mL.
Application volume:
5 µL of each solution.
Developing solvent system:
a mixture of toluene, acetone, and glacial acetic acid (17:8:0.2).
Procedure
Proceed as directed for
Thin-Layer Chromatography under
Chromatography 621. Develop in a chamber previously equilibrated with
Developing solvent system. Examine the plate under long-wavelength UV light. Any secondary spot obtained from the
Test solution is not greater in size or intensity than the spot obtained from
Standard solution 1: not more than 0.02% of free salicylic acid is found.
Chromatographic purity
Mobile phase, Standard preparation, and Chromatographic system
Proceed as directed in the Assay.
Test preparation
Use the Assay preparation.
Procedure
Inject a volume (about 10 µL) of the
Test preparation into the chromatograph, record the chromatogram, and measure all of the peak responses. Calculate the percentage of each impurity in the portion of Trolamine Salicylate taken by the formula:
100(ri / rs),
in which
ri is the peak response for each impurity, and
rs is the sum of the responses of all the peaks: not more than 1.0% of any individual impurity is found, and not more than 2.0% of total impurities is found.
Assay
Mobile phase
Prepare a filtered and degassed mixture of water and acetonitrile (7:3). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard preparation
Dissolve an accurately weighed quantity of
USP Salicylic Acid RS in methanol, and dilute quantitatively, and stepwise if necessary, with methanol to obtain a solution having a known concentration of about 48 µg per mL.
Assay preparation
Transfer a portion of Trolamine Salicylate, equivalent to about 300 mg of salicylic acid, accurately weighed, to a 250-mL volumetric flask, and dilute with methanol to volume. Transfer 2 mL of this solution to a 50-mL volumetric flask, dilute with methanol to volume, and mix.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 308-nm detector and a 4.0-mm × 12.5-cm column that contains packing L1. The flow rate is about 1 mL per minute. The column temperature is maintained at 30
. Chromatograph the
Standard preparation, and record the peak responses as directed for
Procedure: the column efficiency is not less than 8000 theoretical plates; the tailing factor is not more than 1.5; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 10 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the percentage of C
13H
21NO
6 in the portion of Trolamine Salicylate taken by the formula:
100(rU / rS),
in which
rU and
rS are the peak responses obtained from the
Assay preparation and the
Standard preparation, respectively.