U.S. PHARMACOPEIA

Search USP29  
Temazepam
Click to View Image
C16H13ClN2O2 300.74

2H-1,4-Benzodiazepin-2-one, 7-chloro-1,3-dihydro-3-hydroxy-1-methyl-5-phenyl-.
7-Chloro-1,3-dihydro-3-hydroxy-1-methyl-5-phenyl-2H-1,4-benzodiazepin-2-one [846-50-4].
» Temazepam contains not less than 98.0 percent and not more than 102.0 percent of C16H13ClN2O2, calculated on the dried basis.
Caution—Temazepam is a potent sedative: its powder should not be inhaled.
Packaging and storage— Preserve in well-closed, light-resistant containers.
Identification—
A: The IR absorption spectrum of a potassium bromide dispersion of it, previously dried, exhibits maxima only at the same wavelengths as that of a similar preparation of USP Temazepam RS.
B: The UV absorption spectrum of a 1 in 80,000 solution in methanol exhibits maxima and minima at the same wavelengths as that of a similar solution of USP Temazepam RS, concomitantly measured.
C: The retention time of the major peak in the chromatogram of the Assay preparation corresponds to that of the Standard preparation, both relative to the internal standard, as obtained in the Assay.
Loss on drying 731 Dry it at 105 for 2 hours; it loses not more than 0.5% of its weight.
Residue on ignition 281: not more than 0.1%.
Heavy metals, Method II 231: 20 ppm.
Chromatographic purity—
Standard stock solution— Dissolve an accurately weighed quantity of USP Temazepam RS in chloroform, and dilute quantitatively and stepwise with chloroform to obtain a solution having a known concentration of about 10 mg per mL.
Standard solutions A and B— Dilute accurately measured volumes of Standard stock solution quantitatively with chloroform to obtain Standard solutions A and B having known concentrations of about 0.1 and 0.05 mg per mL, respectively.
Test solution— Transfer about 100 mg of Temazepam, accurately weighed, to a 10-mL volumetric flask, add chloroform to volume, and mix.
Procedure— Separately apply 10 µL of the Test solution and 10 µL of each Standard solution to a thin-layer chromatographic plate (see Chromatography 621) coated with a 0.25-mm layer of chromatographic silica gel mixture. Position the plate in a chromatographic chamber, and develop the chromatograms in a solvent system consisting of cyclohexane, chloroform, methanol, and ammonium hydroxide (50:40:12:1) until the solvent front has moved about 10 cm above the point of application. Remove the plate from the developing chamber, mark the solvent front, and allow the solvent to evaporate. Examine the plate under short-wavelength UV light, and compare the intensities of any secondary spots observed in the chromatogram of the Test solution with those of the principal spots in the chromatograms of the Standard solutions: no secondary spot obtained from the Test solution is greater in intensity than 1.0%, and the sum of the intensities of secondary spots obtained from the test solution corresponds to not more than 2.0%.
Residual solvents 467: meets the requirements.
(Official January 1, 2007)
Assay—
Buffer solution— Dissolve 5.444 g of monobasic potassium phosphate in 2000 mL of water. Adjust with phosphoric acid to a pH of 3.0.
Mobile phase— Prepare a filtered and degassed mixture of Buffer solution and acetonitrile (53:47). Make adjustments if necessary (see System Suitability under Chromatography 621).
Internal standard solution— Dissolve an accurately weighed quantity of benzophenone in a mixture of methanol and water (9:1), and dilute quantitatively and stepwise with the same solvent to obtain a solution having a concentration of 0.2 mg per mL.
Standard preparation— Dissolve an accurately weighed quantity of USP Temazepam RS in Internal standard solution to obtain a solution having a known concentration of 0.2 mg per mL.
Assay preparation— Transfer about 40.0 mg of temazepam, accurately weighed, to a 200-mL volumetric flask, add about 150 mL of Internal standard solution, mix, and dilute with Internal standard solution to volume.
Chromatographic system (see Chromatography 621)—The liquid chromatograph is equipped with a 254-nm detector and a 4-mm × 25-cm column that contains packing L16. The flow rate is about 2 mL per minute. Chromatograph the Standard preparation, and record the peak responses as directed for Procedure: the column efficiency is not less than 800 theoretical plates; the tailing factor is not more than 2; the resolution between the temazepam peak and any other peak is not less than 1, and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure— Separately inject equal volumes (about 10 µL) of the Standard preparation and the Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. The relative retention times are about 1.0 for temazepam and 2.0 for benzophenone. Calculate the quantity, in mg, of C16H13O2N2Cl in the portion of Temazepam taken by the formula:
200C(RU / RS),
in which C is the concentration, in mg per mL, of USP Temazepam RS in the Standard preparation, and RU and RS are the peak response ratios obtained from the Assay preparation and the Standard preparation, respectively.
Auxiliary Information— Staff Liaison : Ravi Ravichandran, Ph.D., Senior Scientist
Expert Committee : (MDPP05) Monograph Development-Psychiatrics and Psychoactives
USP29–NF24 Page 2077
Phone Number : 1-301-816-8330