Assay
Mobile solvent
Prepare a mixture of isooctane, tetrahydrofuran, and alcohol (89:10:1).
Standard preparation
Dissolve a suitable quantity of
USP Prednisolone Tebutate RS, accurately weighed, in a mixture of tetrahydrofuran and isooctane (1:1) to obtain a solution having a known concentration of about 1 mg per mL.
Assay preparation
Weigh accurately about 50 mg of Prednisolone Tebutate, transfer to a 50-mL volumetric flask, dilute with tetrahydrofuran and isooctane (1:1) to volume, and mix.
Procedure
Inject separately 25-µL volumes of the
Standard preparation and the
Assay preparation into a suitable high-pressure liquid chromatograph equipped with a constant flow pump and a 30-cm × 3.9-mm column that contains packing L3, is operated at 25
, and is equipped with an UV detector capable of monitoring absorption at 254 nm. The flow rate is about 1.0 mL per minute. The retention time for Prednisolone Tebutate is about 30 minutes, but the chromatogram is run for about 45 minutes. Five replicate injections of the
Standard preparation show a relative standard deviation of not more than 1.5%. Calculate the quantity, in mg, of C
27H
38O
6 in the portion of Prednisolone Tebutate taken by the formula:
50C(RU / RS),
in which
C is the concentration, in mg per mL, of
USP Prednisolone Tebutate RS in the
Standard preparation, and
RU and
RS are the peak areas obtained from the
Assay preparation and the
Standard preparation, respectively.