Assay
Standard preparation
Dissolve an accurately weighed quantity of
USP Physostigmine Salicylate RS in acetonitrile, and dilute quantitatively, and stepwise if necessary, with acetonitrile, to obtain a solution having a known concentration of about 30 µg per mL.
Assay preparation
Transfer an accurately measured volume of Ophthalmic Solution, equivalent to about 3 mg of physostigmine salicylate, to a 100-mL volumetric flask, dilute with acetonitrile to volume, and mix.
Chromatographic system
(see
Chromatography 621)The liquid chromatograph is equipped with a 254-nm detector and a 3.9-mm × 30-cm column that contains packing L1. The flow rate is about 2 mL per minute. Chromatograph the
Standard preparation and record the peak responses as directed for
Procedure: the column efficiency determined from the analyte peak is not less than 1200 theoretical plates, and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Proceed as directed for
Procedure in the
Assay under
Physostigmine Salicylate Injection. Calculate the quantity, in mg, of C
15H
21N
3O
2·C
7H
6O
3 in each mL of the Ophthalmic Solution taken by the formula:
0.1(C / V)(rU / rS),