Dissolution 711
Medium:
0.0005% (w/v) polysorbate 80; 500 mL.
Apparatus 2:
75 rpm.
Time:
60 minutes.
Determine the amount of C21H28O2 and C20H24O2 dissolved by employing the following method. [NoteDo not use plastics during the preparation of solutions.]
Mobile phase
Prepare a filtered and degassed mixture of water and acetonitrile (3:2). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard solution
[NoteA volume of alcohol not exceeding 2% of the final volume of the solution may be used to aid in dissolving the USP Reference Standards.
]Dissolve an accurately weighed quantity of
USP Norgestrel RS and
USP Ethinyl Estradiol RS in
Medium, and dilute quantitatively, and stepwise if necessary, with
Medium to obtain a solution having known concentrations similar to those expected in the
Test solution.
Test solution
Use a portion of the solution under test filtered through 0.7-µm borosilicate microfiber filter.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 247-nm detector (for norgestrel analysis), and a spectrofluorometric detector (for ethinyl estradiol analysis) with an excitation wavelength of about 285 nm and an emission wavelength of 310 nm, and a 4.6-mm × 15-cm column that contains packing L7. The flow rate is about 1 mL per minute. Chromatograph the
Standard solution, and record the peak responses as directed for
Procedure: the relative retention times are about 0.7 for ethinyl estradiol and 1.0 for norgestrel; and the relative standard deviation for replicate injections is not more than 3.0% for the ethinyl estradiol and norgestrel peaks.
Procedure
Separately inject equal volumes (about 100 µL) of the
Standard solution and the
Test solution into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantities, in mg, of norgestrel (C
21H
28O
2) and ethinyl estradiol (C
20H
24O
2) dissolved by the formula:
(500C)(rU / rS),
in which
C is the concentration, in mg per mL, of the appropriate USP Reference Standard in the
Standard solution; and
rU and
rS are the peak responses obtained from the
Test solution and the
Standard solution, respectively.
Tolerances
Not less than 75% (Q) of the labeled amount of C21H28O2 and C20H24O2 is dissolved in 60 minutes.
Assay
Mobile phase
Prepare a degassed mixture of water, acetonitrile, and methanol (45:35:15). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard preparation
Dissolve an accurately weighed quantity of
USP Norgestrel RS and
USP Ethinyl Estradiol RS in
Mobile phase, and dilute quantitatively, and stepwise if necessary, with
Mobile phase to obtain a solution having known concentrations of about 100 µg of norgestrel per mL and 10 µg of ethinyl estradiol per mL.
Assay preparation
Transfer an accurately counted number of Tablets, equivalent to about 10 mg of norgestrel, to a 200-mL volumetric flask. Add 100.0 mL of Mobile phase, accurately measured, sonicate for 10 minutes to disintegrate the Tablets, and shake by mechanical means for 20 minutes. Centrifuge the clear portion of the solution at about 2000 rpm for 10 minutes, and filter the clear supernatant.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 215-nm detector and a 4.6-mm × 15-cm column that contains 5-µm packing L7. The flow rate is about 1 mL per minute. Chromatograph the
Standard preparation, and record the peak responses as directed for
Procedure: the relative retention times are about 1.0 for ethinyl estradiol and 1.5 for norgestrel; the resolution,
R, between the two major peaks is not less than 2.5; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 50 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of ethinyl estradiol (C
20H
24O
2) and norgestrel (C
21H
28O
2) in the portion of Tablets taken by the formula:
100C(rU / rS),
in which
C is the concentration, in mg per mL, of the relevant USP Reference Standard in the
Standard preparation; and
rU and
rS are the peak responses for the relevant analyte obtained from the
Assay preparation and the
Standard preparation, respectively.