Assay
Internal standard solution
Prepare a solution in methylene chloride containing 1 mg of n-docosane in each mL.
Standard preparation
Dissolve an accurately weighed quantity of
USP Lindane RS in methylene chloride to obtain a solution having a known concentration of about 2 mg per mL. Transfer 5.0 mL of this solution to a graduated centrifuge tube, add 5.0 mL of
Internal standard solution, mix, and evaporate with the aid of gentle heat and a current of dry air to 3 mL.
[NOTEAvoid evaporating to dryness. If the mixture is inadvertently evaporated to dryness, discard it, and begin another
Standard preparation.]
Solid support
Use 60- to 100-mesh magnesium silicate that has been previously heated at 300
for 2 hours.
Mobile phase
Mix 18 mL of anhydrous ethyl ether with 280 mL of chromatographic solvent hexane.
Assay preparation
Place a pledget of cotton on a removable porous plate at the base of a 25-mm × 200-mm chromatographic tube that is fitted with a polytef stopcock. Add 50 mL of Mobile phase and 10 g of Solid support, and stir the mixture to expel air bubbles. Add 1.5 g of anhydrous sodium sulfate to the column, and elute until the surface of the liquid is about 4 cm above the Solid support, discarding the eluate. Transfer an accurately weighed portion of Cream, corresponding to about 10 mg of lindane, to a 150-mL beaker, and add 10 g of Solid support. Mix with a spatula, adding chromatographic solvent hexane as necessary to produce a homogeneous mixture, and continue stirring until a free-flowing powder is produced. Transfer this mixture to the chromatographic column with the aid of three 5-mL portions of Mobile phase, and elute the column with 225 mL of the Mobile phase at a flow rate of 2 mL to 3 mL per minute, collecting the eluate in a 250-mL beaker. Remove the chromatographic column, add 5.0 mL of Internal standard solution to the eluate, and evaporate with the aid of gentle heat and a current of dry air to about 5 mL. Transfer this solution to a graduated centrifuge tube with the aid of 1 mL of methylene chloride, and evaporate with the aid of gentle heat and a current of dry air to about 3 mL. [See Note under Standard preparation.]
Chromatographic system (see Chromatography 621)
The gas chromatograph is equipped with a flame-ionization detector and contains a 1.8-m × 2-mm glass column packed with 3% liquid phase G3 on support S1A. Maintain the column temperature at 195
, and maintain the injection port and the detector temperatures at 250
. Use dry nitrogen as the carrier gas at a flow rate of about 40 mL per minute. Chromatograph six to ten replicate injections of the
Standard preparation, and record the peak responses as directed for
Procedure: the relative standard deviation is not more than 3.0%; the tailing factor is not more than 2.0; and the resolution factor between lindane and
n-docosane is not less than 5.
Procedure
Separately inject equal volumes (about 1 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the percentage of C
6H
6Cl
6 in the Cream taken by the formula:
500(C/W)(RU / RS),
in which
C is the concentration, in mg per mL, of
USP Lindane RS in the solution prepared, prior to the addition of
Internal standard solution, for the
Standard preparation; W is the weight, in mg, of Cream taken; and
RU and
RS are the ratios of the peak responses of lindane to those of
n-docosane from the
Assay preparation and the
Standard preparation, respectively.