Change to read:
Assay for lidocaine hydrochloride
Mobile phase
Mix 50 mL of glacial acetic acid and 930 mL of water, and adjust with 1 N sodium hydroxide to a pH of 3.40. Mix about 4 volumes of this solution with 1 volume of acetonitrile, so that the retention time of lidocaine is about 4 to 6 minutes. Pass through a membrane filter having a 1-µm or finer porosity, and degas. Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Standard preparation
Dissolve about 85 mg of
USP Lidocaine RS, accurately weighed, with warming if necessary, in 0.5 mL of 1 N hydrochloric acid in a 50-mL volumetric flask, dilute with
Mobile phase to volume, and mix to obtain a
Standard preparation having a known concentration of about 1.7 mg of lidocaine per mL.
Assay preparation
Transfer an accurately measured volume of Injection, equivalent to about 100 mg of lidocaine hydrochloride, to a 50-mL volumetric flask, dilute with Mobile phase to volume, and mix.
Resolution preparation
Prepare a solution of methylparaben in Mobile phase containing about 220 µg per mL. Mix 2 mL of this solution and 20 mL of the Standard preparation.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 254-nm detector and a 3.9-mm × 30-cm column that contains packing L1.
USP29 The flow rate is about 1.5 mL per minute. Chromatograph about 20 µL of the
Resolution preparation, and record the peak responses as directed for
Procedure: the resolution,
R, between lidocaine and methylparaben is not less than 3.0. Chromatograph the
Standard preparation, and record the peak responses as directed for
Procedure: the relative standard deviation for replicate injections is not more than 1.5%.
Procedure
Separately inject equal volumes (about 20 µL) of the
Assay preparation and the
Standard preparation into the chromatograph. Record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of lidocaine hydrochloride (C
14H
22N
2O·HCl) in each mL of the Injection taken by the formula:
(270.80/234.34)(50)(C/V)(rU / rS)
in which 270.80 and 234.34 are the molecular weights of lidocaine hydrochloride and lidocaine, respectively;
C is the concentration, in mg per mL, of
USP Lidocaine RS in the
Standard preparation; V is the volume, in mL, of Injection taken; and
rU and
rS are the lidocaine peak responses obtained from the
Assay preparation and the
Standard preparation, respectively.
Change to read:
Assay for epinephrine
Mobile phase
Mix 50 mL of glacial acetic acid and 930 mL of water, and adjust with 1 N sodium hydroxide to a pH of 3.40. Dissolve 1.1 g of sodium 1-heptanesulfonate in this solution, add 1.0 mL of 0.1 M edetate disodium, and mix. Mix about 9 volumes of this solution with 1 volume of methanol, so that the retention time of epinephrine is about 4 to 6 minutes. Pass through a membrane filter having a 1-µm or finer porosity, and degas.
Standard preparation
Dissolve an accurately weighed quantity of
USP Epinephrine Bitartrate RS in
Mobile phase to obtain a solution having a known concentration of about 9 µg of epinephrine bitartrate per mL. Pipet 10 mL of this solution into a 50-mL volumetric flask, dilute with
Mobile phase to volume, and mix to obtain a
Standard preparation having a known concentration of about 1.8 µg of epinephrine bitartrate per mL.
Assay preparation
Transfer an accurately measured volume of Injection, equivalent to about 50 µg of epinephrine, to a 50-mL volumetric flask, dilute with Mobile phase to volume, and mix.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is fitted with a 3.9-mm × 30-cm stainless steel column that contains packing L1 and is equipped with an electrochemical detector held at a potential of +650 mV, a controller capable of regulating the background current, and a suitable recorder.
USP29 The flow rate is about 1 mL per minute. Chromatograph the
Standard preparation as directed for
Procedure: the relative standard deviation of the peak responses of successive injections of the
Standard preparation is not more than 1.5%.
Procedure
Separately inject equal volumes (about 20 µL) of the
Assay preparation and the
Standard preparation into the chromatograph by means of a suitable microsyringe or sampling valve, adjusting the specimen size and other operating parameters so that satisfactory chromatography and peak responses are obtained. Record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in µg, of epinephrine (C
9H
13NO
3) in each mL of the Injection taken by the formula:
(183.20/333.29)(50)(C/V)(rU / rS)
in which 183.20 and 333.29 are the molecular weights of epinephrine and epinephrine bitartrate, respectively;
C is the concentration, in µg per mL, of
USP Epinephrine Bitartrate RS in the
Standard preparation; V is the volume, in mL, of Injection taken; and
rU and
rS are the peak responses obtained from the
Assay preparation and the
Standard preparation, respectively.