Packaging and storage
Preserve in well-closed containers. Store at 25
, excursions permitted between 15
and 30
.
Related compounds
Mobile phase
Dissolve 0.95 g of sodium 1-hexanesulfonate in 1 L of a solution consisting of a mixture of water and acetonitrile (3:1). Add 4 mL of acetic acid, and mix.
Test solution
Transfer an accurately weighed quantity of about 50.0 mg of Ketamine Hydrochloride to a 50-mL volumetric flask. Dissolve in and dilute with Mobile phase to volume, sonicating if necessary.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 215-nm detector and a 4.0-mm × 4.0-mm guard column with a 4.0-mm × 12.5-cm analytical column that contains 5-µm packing L1. The flow rate is about 1.0 mL per minute. Chromatograph the
Standard solution, and record the peak responses as directed for
Procedure: the order of elution is ketamine hydrochloride followed by ketamine related compound A; the resolution,
R, between these two peaks is not less than 2.0; the retention time of ketamine hydrochloride is between 3.0 and 4.5 minutes (if necessary, adjust the concentration of water and acetonitrile); and the tailing factor is not greater than 1.5.
Procedure
Separately inject equal volumes (about 20 µL) of the
Standard solution and the
Test solution into the chromatograph, record the chromatograms, identify the ketamine hydrochloride and ketamine related compound A peaks, and measure the areas of the major peaks. Calculate the area percentage of each impurity, relative to ketamine hydrochloride, in the portion of Ketamine Hydrochloride taken by the formula:
5000(C/W)(ri / rS),
in which
C is the concentration, in mg per mL, of
USP Ketamine Hydrochloride RS in the
Standard solution; W is the weight, in mg, of Ketamine Hydrochloride taken to prepare the
Test solution; ri is the peak area of each individual impurity peak in the
Test solution; and
rS is the response of the ketamine hydrochloride peak obtained from the
Standard solution. Not more than 0.1% of ketamine related compound A is found; the response of no other unknown impurity is greater than 0.3% of the ketamine peak area; and the sum of the responses of all unknown impurity peaks is not greater than 1.0% of the ketamine peak response.
Assay
Buffer
Dissolve 5.75 g of monobasic ammonium phosphate in 1000 mL of water. Add 6 mL of triethylamine, and adjust with phosphoric acid to a pH of 3.0.
Mobile phase
Prepare a filtered and degassed mixture of
Buffer and methanol (65:35). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
System suitability solution
Transfer about 12.5 mg each, of
USP Ketamine Hydrochloride RS and
USP Ketamine Related Compound A RS, both accurately weighed, to a 50-mL volumetric flask, dissolve in
Mobile phase with the aid of sonification if necessary, dilute with
Mobile phase to volume, and mix. Transfer 10.0 mL of the solution so obtained to a 100-mL volumetric flask, dilute with
Mobile phase to volume, and mix.
Standard preparation
Transfer about 10 mg of
USP Ketamine Hydrochloride RS, accurately weighed, to a 50-mL volumetric flask, add about 20 mL of
Mobile phase, and sonicate to dissolve. Dilute with
Mobile phase to volume, and mix.
Assay preparation
Transfer about 20 mg of Ketamine Hydrochloride, accurately weighed, to a 100-mL volumetric flask, add about 35 mL of Mobile phase, and sonicate to dissolve. Dilute with Mobile phase to volume, and mix.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 220-nm detector and a 4.6-mm × 25-cm column that contains 5-µm packing L1. The flow rate is about 1.0 mL per minute. Chromatograph the
System suitability solution, and record the peak responses as directed for
Procedure: the order of elution is ketamine followed by ketamine related compound A; the resolution,
R, between ketamine and ketamine related compound A is not less than 2.0; the column efficiency determined from the ketamine peak is not less than 9400 theoretical plates; and the tailing factor determined from the ketamine peak is not more than 1.6. Chromatograph the
Standard preparation, and record the ketamine peak response as directed for
Procedure: the relative standard deviation for replicate injections is not more than 0.6%.
Procedure
Separately inject equal volumes (about 20 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of C
13H
16ClNO· HCl in the portion of Ketamine Hydrochloride taken by the formula:
100C(rU / rS),
in which
C is the concentration, in mg per mL, of
USP Ketamine Hydrochloride RS in the
Standard preparation; and
rU and
rS are the ketamine peak responses obtained from the
Assay preparation and the
Standard preparation, respectively.