Packaging and storage
Preserve in single-dose containers, and store in a refrigerator for not more than 12 hours. [NOTETranslucent protein particles may develop, which are removed by filtration prior to administration using a 0.22 micron low-protein-binding filter.]
Labeling
Label it to include the following in addition to the information specified for
Labeling under
Injections 1: the time and date of calibration; the amount of
111In Ibritumomab Tiuxetan as total MBq (or mCi) and concentration of MBq (or mCi) per mL at the time of calibration; the expiration date and time; the storage temperature; and the statement, CautionRadioactive Material. The labeling indicates that, in making dosage calculations, correction is to be made for radioactive decay, and also indicates that the radioactive half-life of
111In is 67.3 hours.
Bacterial endotoxins 85
The limit of endotoxin content is not more than 175/
V USP Endotoxin Units per mL of the Injection, when compared with the USP Endotoxin RS, in which
V is the maximum recommended total dose, in mL, at the expiration date or time.
Radiochemical purity
Absorbent:
1- × 8-cm instant silica gel strip.
Test solution:
the Injection.
Application volume:
10 µL.
Developing solvent system:
0.9 % sodium chloride solution.
Procedure
Proceed as directed for
Thin-Layer Chromatography under
Chromatography 621 by ascending chromatography. Determine the distribution of radioactivity on the chromatogram by scanning with a suitable collimated radiochromatogram strip scanner, and determine the percentage of radiochemical purity of the test specimen. Not less than 95% of the In 111 activity is present as a band between the
RF values of 0 and 0.1.
Other requirements
It meets the requirements for
Radionuclide identification and
Radionuclidic purity under
Indium In 111 Chloride Solution. It meets also the requirements under
Injections 1, except that the radioactive component may be distributed or dispensed prior to completion of the test for
Sterility, the latter test being started on the date of manufacture.
Assay for radioactivity 821
Using a suitable counting assembly (see
Selection of a Counting Assembly), determine the total radioactivity, in MBq (or µCi) of the unshielded Injection by use of a calibrated system.