Limit of phenol
Phenol solution, Standard solution, Test solution, and Chromatographic system
Prepare as directed under Chromatographic purity.
Procedure
Separately inject equal volumes (about 1 µL) of the
Standard solution and the
Test solution into the chromatograph, record the chromatograms, and measure the peak area responses. Calculate the percentage of phenol in the portion of Phenoxyethanol taken by the formula:
150(C/W)(rU / rS),
in which
C is the concentration, in mg per mL, of phenol in the
Standard solution; W is the weight of Phenoxyethanol, in mg, taken to prepare the
Test solution; and
r U and
r S are the peak areas of the phenol peak in the chromatograms obtained from the
Test solution and the
Standard solution, respectively: not more than 0.1% is found.
Chromatographic purity
Phenol solution
Prepare a solution of phenol in isopropyl alcohol having a known concentration of about 0.25 mg of phenol per mL.
Standard solution
Dissolve an accurately weighed quantity of USP Phenoxyethanol RS in Phenol solution to obtain a solution having a known concentration of about 5 mg of phenoxyethanol per mL. Accurately transfer 500 µL of this solution to a vial, add 1000 µL of isopropyl alcohol, crimp the vial, and mix on a vortex mixer for about 15 seconds.
Test solution
Accurately transfer 500 µL of Phenoxyethanol to a tared vial, and determine the weight of Phenoxyethanol taken. Add 1000 µL of isopropyl alcohol, crimp the vial, and mix on a vortex mixer for about 15 seconds.
Chromatographic system (see Chromatography 621)
The gas chromatograph is equipped with a flame-ionization detector and a 0.32-mm × 10-m capillary column coated with a 5-µm film of stationary phase G27. The carrier gas is helium with a split flow rate of 44 mL per minute. The injector port temperature and the detector temperature are both maintained at 300
. The column temperature is programmed as follows: the starting column temperature is 80
; after injection, it is increased to 260
at a rate of 8
per minute, then held for 10 minutes. Chromatograph the
Standard solution, and record the peak responses as directed for
Procedure: the resolution,
R, between phenol and phenoxyethanol peaks is not less than 10; and the relative standard deviation for replicate injections for the phenoxyethanol peak is not more than 2.0%.
Procedure
Separately inject equal volumes (about 1 µL) of the
Standard solution and the
Test solution into the chromatograph, record the chromatograms, and measure the peak area responses. Calculate the percentage of total impurities in the portion of Phenoxyethanol taken by the formula:
150(C/W)(rU / rS),
in which
C is the concentration, in mg per mL, of phenoxyethanol in the
Standard solution; W is the weight of Phenoxyethanol, in mg, taken to prepare the
Test solution; rU is the sum of all additional peak areas in the chromatogram obtained from the
Test solution, excluding the main peak, the solvent peak, and the phenol peak; and
rS is the peak area of the phenoxyethanol peak in the chromatogram obtained from the
Standard solution: not more than 1.0% of total impurities is found.
Assay
Phenol solution and Chromatographic system
Prepare as directed under Chromatographic purity.
Standard preparation
Use the
Standard solution, prepared as directed under
Chromatographic purity.
Assay preparation
Transfer about 500 mg of Phenoxyethanol, accurately weighed, to a 100-mL volumetric flask, dissolve in and dilute with isopropyl alcohol to volume, and mix. Accurately transfer 500 µL of this solution to a vial, add 1000 µL of isopropyl alcohol, crimp the vial, and mix on a vortex mixer for about 15 seconds.
Procedure
Separately inject equal volumes (about 1 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the peak area responses. Calculate the quantity, in mg, of C
8H
10O
2 in the portion of Phenoxyethanol taken by the formula:
150C(rU / rS),
in which
C is the concentration, in mg per mL, of USP Phenoxyethanol RS in the
Standard preparation; and
rU and
rS are the responses of the phenoxyethanol peak obtained from the
Assay preparation and the
Standard preparation, respectively.