Related compounds
Diluent
Prepare a mixture of water and acetonitrile (11:9).
Mobile phase
Prepare a filtered and degassed mixture of water, acetonitrile, and glacial acetic acid (12:7:1). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
System suitability solution
Pipet 2.0 mL of
Standard stock solution into a 10-mL volumetric flask, add about 20 mg of
USP Flurbiprofen RS, dilute with
Diluent to volume, and mix.
Standard solution
Transfer 2.0 mL of Standard stock solution to a 10.0-mL volumetric flask, dilute with Diluent to volume, and mix.
Test solution
Prepare a solution of Flurbiprofen in Diluent containing 2.0 mg per mL.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 254-nm detector and a 3.9-mm × 15-cm column that contains 4-µm packing L1. The flow rate is about 1 mL per minute. Chromatograph the
System suitability solution, and record the peak responses as directed for
Procedure: the relative retention times are about 0.9 for flurbiprofen related compound A and 1.0 for flurbiprofen; and the relative standard deviation for replicate injections is not more than 1.0%.
Procedure
Separately inject equal volumes (about 20 µL) of the
Standard solution and the
Test solution into the chromatograph, record the chromatograms, and measure the areas for the major peaks. Calculate the percentage of flurbiprofen related compound A in the portion of Flurbiprofen taken by the formula:
100(CS / CU)(rU / rS),
in which
CS is the concentration, in µg per mL, of
USP Flurbiprofen Related Compound A RS in the
Standard solution; CU is the concentration, in µg per mL, of Flurbiprofen in the
Test solution; and
rU and
rS are the peak responses for flurbiprofen related compound A obtained from the
Test solution and the
Standard solution, respectively: not more than 0.5% of flurbiprofen related compound A is found. Calculate the percentage of each impurity in the portion of Flurbiprofen taken by the formula:
100(ri / rs),
in which
ri is the peak response for each impurity obtained from the
Test solution; and
rs is the sum of the responses of all the peaks obtained from the
Test solution: the sum of all impurities is not more than 1.0%.