Packaging and storage
Preserve in well-closed containers. Store at 25
, excursions permitted between 15
and 30
.
Chromatographic purity
Solution A
Prepare a filtered and degassed mixture of water and acetonitrile (7:3). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Solution B
Prepare a filtered and degassed mixture of acetonitrile and water (7:3). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
Mobile phase
Use variable mixtures of Solution A and Solution B as directed for Chromatographic system.
Diluting solution
Prepare a filtered mixture of acetonitrile, water, and glacial acetic acid (7:3:0.1).
Standard solution
Dissolve an accurately weighed quantity of
USP Cortisone Acetate RS in
Diluting solution, and dilute quantitatively, and stepwise if necessary, with
Diluting solution to obtain a solution having a known concentration of about 20 µg per mL.
Test solution
Transfer about 25 mg of Cortisone Acetate, accurately weighed, to a 10-mL volumetric flask, dissolve in and dilute with Diluting solution to volume, sonicate, and mix.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 254-nm detector and a 4.6-mm × 15-cm column that contains packing L1. The flow rate is about 1 mL per minute. The chromatograph is programmed as follows.
Time
|
Solution A
(%) |
Solution B
(%) |
Elution |
0 |
90 |
10 |
equilibration |
05 |
90 |
10 |
isocratic |
525 |
90®10 |
10®90 |
linear gradient |
2530 |
10 |
90 |
isocratic |
3031 |
10®90 |
90®10 |
linear gradient |
3151 |
90 |
10 |
isocratic |
Chromatograph the
Standard solution, and record the peak responses as directed for
Procedure: the relative standard deviation for replicate injections is not more than 5.0%.
Procedure
Separately inject equal volumes (about 15 µL) of the
Standard solution and the
Test solution into the chromatograph, record the chromatograms, and measure the peak responses. Calculate the percentage of each impurity in the portion of Cortisone Acetate taken by the formula:
1000(C/W)(ri / rS),
in which
C is the concentration, in mg per mL, of
USP Cortisone Acetate RS in the
Standard solution; W is the amount, in mg, of Cortisone Acetate taken for the
Test solution; ri is the response for each impurity; and
rS is the response of the major peak in the
Standard solution: not more than 1.5% of any individual impurity is found; and not more than 2.0% of total impurities is found.
Assay
Mobile phase
Prepare a filtered and degassed mixture of water and acetonitrile (550:450). Make adjustments if necessary (see
System Suitability under
Chromatography 621).
pH 4 Buffer solution
Transfer 20 mL of 1 N hydrochloric acid, 150 mL of 0.5 N potassium chloride, and 50 mL of 0.5 M sodium acetate to a 1-L volumetric flask, dilute with water to volume, and mix.
Diluent solution
Prepare a mixture of acetonitrile and pH 4 Buffer solution (1:1).
Standard preparation
Transfer about 25 mg of
USP Cortisone Acetate RS, accurately weighed, to a 250-mL volumetric flask. Add 100 mL of
Diluent solution, sonicate until a clear solution is obtained, and dilute with
Diluent solution to volume.
Assay preparation
Using about 25 mg of Cortisone Acetate, accurately weighed, proceed as directed for Standard preparation.
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 254-nm detector and a 3.9-mm × 30-cm column containing 10-µm packing L1. The flow rate is about 2 mL per minute. Chromatograph the
Standard preparation, and record the peak responses as directed for
Procedure: the column efficiency is not less than 1500 theoretical plates; the tailing factor is not more than 2.0; the capacity factor,
k¢, is not less than 2.0; and the standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 20 µL) of the
Standard preparation and the
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of C
23H
30O
6 in the portion of Cortisone Acetate taken by the formula:
250C(rU / rS),
in which
C is the concentration, in mg per mL, of
USP Cortisone Acetate RS in the
Standard preparation; and
rU and
rS are the cortisone acetate peak responses obtained from the
Assay preparation and the