Assay
Mobile phase
Prepare a filtered and degassed mixture of water, dimethylformamide, glacial acetic acid, and 11.7 N potassium hydroxide (1834:160:4:2). Make adjustments if necessary (see
System Suitability under
Chromatography 621). Increase the proportion of dimethylformamide to decrease the retention time of cephapirin.
Resolution solution
Prepare a solution of Cephapirin Sodium in pH 2.0 hydrochloric acid buffer (see
Buffer Solutions in the section
Reagents, Indicators, and Solutions) containing about 1 mg per mL. Place 10 mL of this solution in a test tube, and heat at 95
for 10 minutes, accurately timed. Promptly cool the tube in an ice water bath. Dilute 5 mL of the cooled solution with
Mobile phase to obtain 50 mL of
Resolution solution.
Standard preparation
Transfer about 21 mg of
USP Cephapirin Sodium RS, accurately weighed, to a 100-mL volumetric flask, dilute with
Mobile phase to volume, and mix. This solution contains about 0.2 mg of cephapirin per mL.
Assay preparation 1 (where it is packaged for dispensing and is represented as being in a single-dose container)
Constitute Cephapirin for Injection in a volume of water, accurately measured, corresponding to the volume of solvent specified in the labeling. Withdraw all of the withdrawable contents, using a suitable hypodermic needle and syringe, and dilute quantitatively, and stepwise if necessary, with Mobile phase to obtain a solution containing the equivalent of about 0.2 mg of cephapirin per mL.
Assay preparation 2 (where the label states the quantity of cephapirin in a given volume of constituted solution)
Constitute Cephapirin for Injection in a volume of water, accurately measured, corresponding to the volume of solvent specified in the labeling. Dilute an accurately measured volume of the constituted solution quantitatively, and stepwise if necessary, with Mobile phase to obtain a solution containing the equivalent of about 0.2 mg of cephapirin per mL. [NOTEUse the Standard preparation and the Assay preparation within 1 hour.]
Chromatographic system (see Chromatography 621)
The liquid chromatograph is equipped with a 254-nm detector and a 4-mm × 30-cm column that contains packing L1. The flow rate is about 2 mL per minute. Chromatograph the
Resolution solution, and record the peak responses as directed for
Procedure: the resolution,
R, between the cephapirin peak and the peak having a retention time of about 0.9 relative to that of cephapirin is not less than 0.9. Chromatograph the
Standard preparation, and record the peak responses as directed for
Procedure: the relative retention times are about 0.9 for cephapirin lactone and 1.0 for cephapirin; the column efficiency determined from the cephapirin peak is not less than 1200 theoretical plates; the tailing factor for the cephapirin peak is not more than 2.0; and the relative standard deviation for replicate injections is not more than 2.0%.
Procedure
Separately inject equal volumes (about 20 µL) of the
Standard preparation and the appropriate
Assay preparation into the chromatograph, record the chromatograms, and measure the responses for the major peaks. Calculate the quantity, in mg, of cephapirin (C
17H
17N
3O
6S
2) withdrawn from the container, or in the portion of constituted solution taken by the formula:
(L/D)(CP/1000)(rU / rS),
in which
L is the labeled quantity, in mg, of cephapirin in the single-dose container, or in the volume of constituted solution taken;
D is the concentration, in mg per mL, of cephapirin in
Assay preparation 1 or in
Assay preparation 2, on the basis of the labeled quantity in the container, or in the portion of constituted solution taken, respectively, and the extent of dilution;
C is the concentration, in mg per mL, of
USP Cephapirin Sodium RS in the
Standard preparation; P is the potency, in µg of cephapirin per mg, of
USP Cephapirin Sodium RS; and
rU and
rS are the cephapirin peak responses obtained from the
Assay preparation and the
Standard preparation, respectively.